Applications across Pakistan

Start from what the pump has to do. Each application lists the CNP series that suit it, taken from the catalogue.

Building water supply and pressure boosting

Domestic and commercial water supply, boosting and pressurising from tanks or mains.

Vertical multistage (CDM, CDL) and horizontal multistage (CM, CHL, CHM) pumps suit high head at moderate flow; TD and ZS suit larger flows at lower head.

What we need to select a pump

  • Required flow and total head, including pipe friction and static lift
  • Number of outlets / peak demand
  • Inlet condition: mains, tank (suction lift or flooded)
  • Electric supply (single / three phase)

Watch out for

  • A single flow-and-head match is not enough: check NPSH on suction lift and start-stop frequency
  • Choose a pump whose duty sits near the middle of its curve, not at the far end
  • Add a pressure tank or variable-speed control if demand varies widely

Series to consider (a flow-and-head match alone does not make a pump suitable)

Find a pump for this Ask our engineers

Constant-pressure (variable-speed) supply

Holds a set pressure by varying motor speed: boosting, building supply, irrigation.

CHME is a complete unit with controller, sensor, check valve, gauge and tank. TDE has a built-in controller and runs up to six pumps.

What we need to select a pump

  • Target pressure at the farthest outlet
  • Minimum and maximum flow demand
  • Inlet pressure available
  • Control method (variable-speed drive or pressure switch)

Watch out for

  • The pump must hold pressure at low flow: check the curve is stable near shut-off
  • Size the pressure tank and drive for the demand profile, not only the peak
  • Verify maximum system pressure against the pump rating

Series to consider (a flow-and-head match alone does not make a pump suitable)

Find a pump for this Ask our engineers

Heating, HVAC and circulation

Circulation for heating, air-conditioning, chilled and domestic hot water.

In-line TD pumps are the usual choice; LDMF suits hot water to 120 °C with low NPSH. Use the fluid and temperature fields for glycol or hot water.

What we need to select a pump

  • Design flow and system head (including coils and valves)
  • Fluid and temperature (water, glycol mixture)
  • Open or closed circuit
  • Duty / standby arrangement

Watch out for

  • Closed circuits need pressure rating and expansion arrangements, not only head
  • Glycol changes density and viscosity: confirm the correction before selecting
  • Quiet running and standby duty are often specified: ask us

Series to consider (a flow-and-head match alone does not make a pump suitable)

Find a pump for this Ask our engineers

Cooling-tower circulation

Large flow at low head for cooling-tower and condenser water circuits.

LLT/LLTS are vertical; WLT/WLTS/WLTSF are horizontal. WLTSF has stainless flow parts.

What we need to select a pump

  • Circulating flow and head to the tower distribution
  • Water quality and temperature
  • Suction arrangement (basin level)
  • Materials required for treated water

Watch out for

  • Low basin level and warm water reduce available NPSH: check it
  • Chemically treated water may need stainless steel parts
  • Do not select only on flow and head; confirm NPSH and materials

Series to consider (a flow-and-head match alone does not make a pump suitable)

Find a pump for this Ask our engineers

Hot water and boiler water

Hot-water supply and boiler-feed duties up to 120 °C.

Choose the hot-water type of CDL/CDM, or LDMF, which is built for high-temperature media and low NPSH.

What we need to select a pump

  • Maximum liquid temperature
  • Flow and head
  • Circuit pressure
  • Seal and elastomer requirements

Watch out for

  • Only series rated for your temperature may be used: the Finder excludes the rest
  • Hot liquid reduces NPSH available; check it against NPSHr
  • Seal and rubber materials must suit the temperature

Series to consider (a flow-and-head match alone does not make a pump suitable)

Find a pump for this Ask our engineers

Wells, boreholes and irrigation

Water from wells and tanks, irrigation and lowering ground water.

SJ is the deep-well submersible; PQ is a shorter submersible for tanks, fountains and boosting. Axial and mixed-flow pumps cover large irrigation flows.

What we need to select a pump

  • Static and pumping water level, well diameter
  • Required flow at delivery head
  • Sand / solids content
  • Supply and cable length

Watch out for

  • The pump must fit the bore and be set below the pumping level
  • Sand shortens life: say if the water carries sand
  • Confirm motor cooling and cable voltage drop for long lowering depths

Series to consider (a flow-and-head match alone does not make a pump suitable)

Find a pump for this Ask our engineers

Large-flow water transfer and fire fighting

Large flows for municipal supply, industrial transfer and fire-water systems.

NSC split-casing pumps cover large flows; NIS end-suction pumps list fire fighting among their uses (none is listed as a certified fire pump).

What we need to select a pump

  • Flow and head at the operating point
  • Liquid and temperature
  • Suction arrangement and NPSH available
  • Duty hours per day

Watch out for

  • Large pumps are sensitive to NPSH and operating range: both must be checked
  • Flow and head alone do not decide efficiency or running cost
  • Ask for the performance curve and efficiency at your duty point

Series to consider (a flow-and-head match alone does not make a pump suitable)

Find a pump for this Ask our engineers

Sewage and waste water

Municipal and building sewage, waste water containing solids and fibres.

WQ submersible pumps and ZW/SP self-priming pumps pass solids and long fibres. Use the solids filter on the Utility pumps page.

What we need to select a pump

  • Flow and head, including pipe friction
  • Type of solids and maximum size to pass
  • Pit dimensions and level control
  • Single or duplex arrangement

Watch out for

  • Solids passage size matters as much as flow and head
  • Do not select a clean-water pump for sewage
  • Check pit volume against start frequency

Series to consider (a flow-and-head match alone does not make a pump suitable)

Find a pump for this Ask our engineers

Drainage, flood control and dewatering

Storm and flood drainage, site dewatering, reservoir transfer.

QZB axial-flow and QHB mixed-flow pumps give the largest flows at low head; QF and WQ suit smaller drainage; SP is self-priming for construction sites.

What we need to select a pump

  • Flow and lift
  • Water type (clean, muddy, with sand)
  • Portable or fixed installation
  • Power supply on site

Watch out for

  • Gritty water needs a drainage-type pump, not a clean-water pump
  • Check the discharge hose / pipe size and friction in the head
  • Confirm float or level control

Series to consider (a flow-and-head match alone does not make a pump suitable)

Find a pump for this Ask our engineers

Chemical and corrosive liquids

Acids, alkalis, solvents and process chemicals.

NIH (stainless process pump) and SZ (fluoroplastic) are the chemical ranges. CHLF(T) is for light chemical media only.

What we need to select a pump

  • Exact chemical, concentration and temperature
  • Flow and head
  • Viscosity and solids content
  • Required wetted materials and seal type

Watch out for

  • Material compatibility decides the selection, not flow and head
  • Confirm density and vapour pressure for suction conditions
  • We confirm the seal and elastomer for your chemical before quoting

Series to consider (a flow-and-head match alone does not make a pump suitable)

Find a pump for this Ask our engineers

High pressure and reverse osmosis

High-pressure supply for reverse-osmosis, ultra-filtration and flushing systems.

CDLF+CDH and CDMF+CMH work as two pumps in series (to about 48 bar). HP is a horizontal high-pressure pump.

What we need to select a pump

  • Feed flow and membrane pressure
  • Water salinity and temperature
  • Pump position (feed / booster)
  • Material requirement

Watch out for

  • High pressure and corrosion resistance both matter
  • Check the pressure rating against the membrane pressure
  • Salty water needs the right stainless or duplex material

Series to consider (a flow-and-head match alone does not make a pump suitable)

Find a pump for this Ask our engineers

Seawater and desalination

Seawater lift and high-pressure seawater reverse-osmosis.

VMHP and CH have duplex stainless wet parts for seawater at up to 75 bar. QF, QZB/QHB and WQ-F handle seawater lifting and drainage.

What we need to select a pump

  • Flow and head
  • Salinity and temperature
  • Immersed or dry installation
  • Material required

Watch out for

  • Standard stainless grades may not suit seawater: confirm the grade
  • Corrosion and galvanic effects depend on the whole installation
  • Do not rely on flow and head alone

Series to consider (a flow-and-head match alone does not make a pump suitable)

Find a pump for this Ask our engineers

Swimming pools

Pool circulation pumps and sand filters.

Pool pumps are for 5–50 °C pool water; pool filters are rated by flow only.

What we need to select a pump

  • Pool volume and turnover time
  • Filter and piping losses
  • Salt or chlorine dosing
  • Supply (single / three phase)

Watch out for

  • Turnover flow and filter head set the duty; check the pump is not oversized
  • Chemical dosing affects material choice
  • Check self-priming and strainer arrangement

Series to consider (a flow-and-head match alone does not make a pump suitable)

Find a pump for this Ask our engineers

Machine-tool coolant and tank immersion

Cooling, lubricating and cleaning circuits where the pump is mounted on a tank.

CDLK/CDLKF are immersion multistage pumps; a cavity body adjusts the pump length to the tank depth.

What we need to select a pump

  • Coolant type, temperature and filtration
  • Flow and head at the machine
  • Tank arrangement
  • Duty cycle

Watch out for

  • Coolant viscosity and swarf change the duty: tell us the fluid
  • Check the seal compatibility with the coolant
  • Confirm immersion depth and mounting

Series to consider (a flow-and-head match alone does not make a pump suitable)

Find a pump for this Ask our engineers

Need a pump or a spare part?

Send us the flow and head you need, or the model code and nameplate details of the pump you are repairing. Our team replies with a quotation.