WLTS (horizontal, extended shaft)
Horizontal cooling-tower circulation pumps, extended-shaft structure, DN65–DN150
As WLT but the pump shaft is a separate extended shaft connected straight to the motor, so the pump end can be serviced without moving the motor. Available at 50 Hz and 60 Hz.
- Large flow, low head: 30–300 m³/h, up to 9 m
- Liquid temperature -15 to +100 °C, working pressure up to 6 bar
- Back-pull-out structure with motor fixed on a base for easy installation and service
- Closed cooling-tower and condenser water circulation, unit-equipment cooling

CNP-S-000089- Flow
- 35–300 m³/h
- Head
- up to 9 m
- Power
- 1.1–7.5 kW
- Mains
- 50 Hz / 60 Hz
- Models
- 16
- Liquid temp.
- -15 to +100 °C
Sizes
| Size | Description | Rated flow | Flow range | Max pressure | Motor | Connection | Models |
|---|---|---|---|---|---|---|---|
| WLTS65 | Horizontal cooling-tower pump, extended-shaft structure, DN65 | 40 m³/h | 35–50 m³/h | 6 bar | 1.1 kW | Flange DN65 | 3 |
| WLTS80 | Horizontal cooling-tower pump, extended-shaft structure, DN80 | 55 m³/h | 50–70 m³/h | 6 bar | 1.5 kW | Flange DN80 | 2 |
| WLTS100 | Horizontal cooling-tower pump, extended-shaft structure, DN100 | 100 m³/h | 55–150 m³/h | 6 bar | 2.2 kW | Flange DN100 | 3 |
| WLTS125 | Horizontal cooling-tower pump, extended-shaft structure, DN125 | 165 m³/h | 120–200 m³/h | 6 bar | 3–4 kW | Flange DN125 | 5 |
| WLTS150 | Horizontal cooling-tower pump, extended-shaft structure, DN150 | 235 m³/h | 190–300 m³/h | 6 bar | 5.5–7.5 kW | Flange DN150 | 3 |
Models
Filter by duty point, mains frequency or size. Click a model for its performance curve and data.
| Model | Size | Stages | Hz | Motor kW | Flow m³/h | Head m | rpm | kg | |
|---|---|---|---|---|---|---|---|---|---|
| WLTS65-5/1.1 | WLTS65 | — | 50 | 1.1 | 35–50 | 3.6–5.8 | 2900 | 33.5 | CurvePDF |
| WLTS80-5/1.5 | WLTS80 | — | 50 | 1.5 | 50–70 | 3–6.4 | 2900 | 41 | CurvePDF |
| WLTS100-5A/2.2 | WLTS100 | — | 50 | 2.2 | 55–100 | 4.3–7 | 1450 | 66 | CurvePDF |
| WLTS100-5/2.2 | WLTS100 | — | 50 | 2.2 | 100–150 | 3.5–6.2 | 1450 | 66 | CurvePDF |
| WLTS125-5A/3 | WLTS125 | — | 50 | 3 | 120–180 | 3.9–6.2 | 1450 | 79 | CurvePDF |
| WLTS125-5/4 | WLTS125 | — | 50 | 4 | 150–200 | 4.1–5.9 | 1450 | 90 | CurvePDF |
| WLTS150-6A/5.5 | WLTS150 | — | 50 | 5.5 | 190–270 | 4.8–7.2 | 1450 | 123 | CurvePDF |
| WLTS150-6/7.5 | WLTS150 | — | 50 | 7.5 | 200–300 | 4.5–7.4 | 1450 | 132.5 | CurvePDF |
| WLTS65-5A/1.1 | WLTS65 | — | 60 | 1.1 | 35–50 | 3.4–5.8 | 3450 | 35 | CurvePDF |
| WLTS65-5/1.5 | WLTS65 | — | 60 | 1.5 | 50–70 | 2–6.4 | 3500 | 42 | CurvePDF |
| WLTS80-5/2.2 | WLTS80 | — | 60 | 2.2 | 55–100 | 2.3–9 | 3500 | 53 | CurvePDF |
| WLTS100-5/3 | WLTS100 | — | 60 | 3 | 100–150 | 3–6.3 | 1750 | 76 | CurvePDF |
| WLTS125-5A/4 | WLTS125 | — | 60 | 4 | 120–180 | 4.1–6.2 | 1750 | 91 | CurvePDF |
| WLTS125-5/4 | WLTS125 | — | 60 | 4 | 150–200 | 4.4–6.6 | 1750 | 91 | CurvePDF |
| WLTS125-6/5.5 | WLTS125 | — | 60 | 5.5 | 190–270 | 4.6–7.8 | 1770 | 112 | CurvePDF |
| WLTS150-6/7.5 | WLTS150 | — | 60 | 7.5 | 200–300 | 4.6–7.4 | 1770 | 138 | CurvePDF |
Performance range
Every model of the WLTS (horizontal, extended shaft) range on one chart: each line is the performance curve of one model. Click a line or dot to open that model with its full data.
- WLTS65
- WLTS80
- WLTS100
- WLTS125
- WLTS150
Logarithmic scales. Published catalogue data for clean water; the correct model for your duty is confirmed by our engineers.
Dimensions & weight
Net weight and the main dimensions of each model, in millimetres, from the catalogue. Open a model for the labelled dimension drawing.
| Model | Hz | Weight (kg) | L1 | H | H1 | L2 | L3 | L7 | L9 |
|---|---|---|---|---|---|---|---|---|---|
| WLTS65-5/1.1 | 50 | 33.5 | 473 | 240 | 120 | 278 | 100 | 278 | 215 |
| WLTS80-5/1.5 | 50 | 41 | 527 | 270 | 130 | 295 | 105 | 294 | 230 |
| WLTS100-5A/2.2 | 50 | 66 | 647 | 380 | 180 | 400 | 155 | 338 | 250 |
| WLTS100-5/2.2 | 50 | 66 | 647 | 380 | 180 | 400 | 155 | 338 | 250 |
| WLTS125-5A/3 | 50 | 79 | 662 | 412 | 212 | 450 | 175 | 353 | 250 |
| WLTS125-5/4 | 50 | 90 | 671 | 412 | 212 | 450 | 175 | 360 | 280 |
| WLTS150-6A/5.5 | 50 | 123 | 695 | 462 | 232 | 510 | 195 | 407 | 350 |
| WLTS150-6/7.5 | 50 | 132.5 | 735 | 462 | 232 | 510 | 195 | 407 | 350 |
| WLTS65-5A/1.1 | 60 | 35 | 460 | 240 | 120 | 278 | 100 | 278 | 215 |
| WLTS65-5/1.5 | 60 | 42 | 480 | 240 | 120 | 278 | 100 | 283 | 230 |
| WLTS80-5/2.2 | 60 | 53 | 490 | 270 | 130 | 295 | 105 | 294 | 230 |
| WLTS100-5/3 | 60 | 76 | 588 | 380 | 180 | 400 | 155 | 338 | 250 |
| WLTS125-5A/4 | 60 | 91 | 620 | 412 | 212 | 450 | 175 | 360 | 280 |
| WLTS125-5/4 | 60 | 91 | 620 | 412 | 212 | 450 | 175 | 360 | 280 |
| WLTS125-6/5.5 | 60 | 112 | 686 | 412 | 212 | 450 | 175 | 404 | 350 |
| WLTS150-6/7.5 | 60 | 138 | 725 | 462 | 232 | 510 | 195 | 407 | 350 |
Spare parts for WLTS (horizontal, extended shaft)
Parts list of the series with the material of each part. To order, send the model code and the part you need.
| No. | Part | Material | Standard | Applies to | |
|---|---|---|---|---|---|
| 1 | Casing | Cast iron HT200 | ASTM 25B | All sizes | |
| 2 | Impeller | Stainless steel ZG07Cr19Ni9 | AISI 304 | All sizes | |
| 3 | Pump head | Cast iron HT200 | ASTM 25B | All sizes | |
| 4 | O-ring seal | NBR | — | All sizes | |
| 5 | Blade mechanical seal | Silicon carbide / tungsten carbide | — | All sizes | |
| 6 | Shaft | Stainless steel 20Cr13 | AISI 420 | All sizes | |
| 7 | Base | Q235-B | AISI A570 | All sizes | |
| 8 | Motor | — | — | All sizes |
Technical data
Liquid temperature
- -15 to +100 °C
Ambient conditions
- Up to +40 °C
Motor
- TEFC motor, IP55, insulation class F; 1×220 V or 3×380 V at 50 Hz
- TEFC motor, IP55, insulation class F; 3×460 V at 60 Hz
Supply voltage
- 1 x 220 V
- 3 x 380 V
- 3 x 460 V
Typical applications
- Water circulation of closed cooling towers and condensers
- Cooling of various unit equipment
- Large-flow, low-head duties
Pumped liquid
- Clean, thin, non-corrosive, non-flammable and non-explosive liquid without solid grains or fibres. A viscous or dense liquid lowers the performance curve and raises energy consumption.
Data basis
- 50 Hz, 2900 / 1450 rpm, 3×380 V, clean water at 20 °C without solid impurities or air; use within the bold part of each curve
- 60 Hz, 3450 / 3500 / 1750 / 1770 rpm, 3×460 V, clean water at 20 °C without solid impurities or air; use within the bold part of each curve
Performance values are taken from the published CNP catalogue data. Our engineers confirm the final selection for your liquid, temperature, supply and site before quoting.
Other cooling-tower pumps
LLTS (extended shaft)
Vertical cooling-tower circulation pump
- Flow 30–480 m³/h
- Head up to 12 m
- 1.1–15 kW
WLTSF (horizontal, stainless flow parts)
Horizontal cooling-tower pump
- Flow 35–300 m³/h
- Head up to 7 m
- 1.1–7.5 kW