Horizontal cooling-tower pump

WLTS (horizontal, extended shaft)

Horizontal cooling-tower circulation pumps, extended-shaft structure, DN65–DN150

As WLT but the pump shaft is a separate extended shaft connected straight to the motor, so the pump end can be serviced without moving the motor. Available at 50 Hz and 60 Hz.

  • Large flow, low head: 30–300 m³/h, up to 9 m
  • Liquid temperature -15 to +100 °C, working pressure up to 6 bar
  • Back-pull-out structure with motor fixed on a base for easy installation and service
  • Closed cooling-tower and condenser water circulation, unit-equipment cooling
WLTS (horizontal, extended shaft)CNP-S-000089
Flow
35–300 m³/h
Head
up to 9 m
Power
1.1–7.5 kW
Mains
50 Hz / 60 Hz
Models
16
Liquid temp.
-15 to +100 °C

Sizes

SizeDescriptionRated flowFlow rangeMax pressureMotorConnectionModels
WLTS65 Horizontal cooling-tower pump, extended-shaft structure, DN65 40 m³/h 35–50 m³/h 6 bar 1.1 kW Flange DN65 3
WLTS80 Horizontal cooling-tower pump, extended-shaft structure, DN80 55 m³/h 50–70 m³/h 6 bar 1.5 kW Flange DN80 2
WLTS100 Horizontal cooling-tower pump, extended-shaft structure, DN100 100 m³/h 55–150 m³/h 6 bar 2.2 kW Flange DN100 3
WLTS125 Horizontal cooling-tower pump, extended-shaft structure, DN125 165 m³/h 120–200 m³/h 6 bar 3–4 kW Flange DN125 5
WLTS150 Horizontal cooling-tower pump, extended-shaft structure, DN150 235 m³/h 190–300 m³/h 6 bar 5.5–7.5 kW Flange DN150 3

Models

Filter by duty point, mains frequency or size. Click a model for its performance curve and data.

Model table (PDF)
ModelSizeStagesHzMotor kWFlow m³/hHead mrpmkg
WLTS65-5/1.1 WLTS65—50 1.1 35–50 3.6–5.8 290033.5 CurvePDF
WLTS80-5/1.5 WLTS80—50 1.5 50–70 3–6.4 290041 CurvePDF
WLTS100-5A/2.2 WLTS100—50 2.2 55–100 4.3–7 145066 CurvePDF
WLTS100-5/2.2 WLTS100—50 2.2 100–150 3.5–6.2 145066 CurvePDF
WLTS125-5A/3 WLTS125—50 3 120–180 3.9–6.2 145079 CurvePDF
WLTS125-5/4 WLTS125—50 4 150–200 4.1–5.9 145090 CurvePDF
WLTS150-6A/5.5 WLTS150—50 5.5 190–270 4.8–7.2 1450123 CurvePDF
WLTS150-6/7.5 WLTS150—50 7.5 200–300 4.5–7.4 1450132.5 CurvePDF
WLTS65-5A/1.1 WLTS65—60 1.1 35–50 3.4–5.8 345035 CurvePDF
WLTS65-5/1.5 WLTS65—60 1.5 50–70 2–6.4 350042 CurvePDF
WLTS80-5/2.2 WLTS80—60 2.2 55–100 2.3–9 350053 CurvePDF
WLTS100-5/3 WLTS100—60 3 100–150 3–6.3 175076 CurvePDF
WLTS125-5A/4 WLTS125—60 4 120–180 4.1–6.2 175091 CurvePDF
WLTS125-5/4 WLTS125—60 4 150–200 4.4–6.6 175091 CurvePDF
WLTS125-6/5.5 WLTS125—60 5.5 190–270 4.6–7.8 1770112 CurvePDF
WLTS150-6/7.5 WLTS150—60 7.5 200–300 4.6–7.4 1770138 CurvePDF

Performance range

Every model of the WLTS (horizontal, extended shaft) range on one chart: each line is the performance curve of one model. Click a line or dot to open that model with its full data.

Logarithmic scales. Published catalogue data for clean water; the correct model for your duty is confirmed by our engineers.

Dimensions & weight

Net weight and the main dimensions of each model, in millimetres, from the catalogue. Open a model for the labelled dimension drawing.

ModelHzWeight (kg)L1HH1L2L3L7L9
WLTS65-5/1.15033.5473240120278100278215
WLTS80-5/1.55041527270130295105294230
WLTS100-5A/2.25066647380180400155338250
WLTS100-5/2.25066647380180400155338250
WLTS125-5A/35079662412212450175353250
WLTS125-5/45090671412212450175360280
WLTS150-6A/5.550123695462232510195407350
WLTS150-6/7.550132.5735462232510195407350
WLTS65-5A/1.16035460240120278100278215
WLTS65-5/1.56042480240120278100283230
WLTS80-5/2.26053490270130295105294230
WLTS100-5/36076588380180400155338250
WLTS125-5A/46091620412212450175360280
WLTS125-5/46091620412212450175360280
WLTS125-6/5.560112686412212450175404350
WLTS150-6/7.560138725462232510195407350

Spare parts for WLTS (horizontal, extended shaft)

Parts list of the series with the material of each part. To order, send the model code and the part you need.

No.PartMaterialStandardApplies to
1CasingCast iron HT200ASTM 25B All sizes
2ImpellerStainless steel ZG07Cr19Ni9AISI 304 All sizes
3Pump headCast iron HT200ASTM 25B All sizes
4O-ring sealNBR— All sizes
5Blade mechanical sealSilicon carbide / tungsten carbide— All sizes
6ShaftStainless steel 20Cr13AISI 420 All sizes
7BaseQ235-BAISI A570 All sizes
8Motor—— All sizes

Technical data

Liquid temperature

  • -15 to +100 °C

Ambient conditions

  • Up to +40 °C

Motor

  • TEFC motor, IP55, insulation class F; 1×220 V or 3×380 V at 50 Hz
  • TEFC motor, IP55, insulation class F; 3×460 V at 60 Hz

Supply voltage

  • 1 x 220 V
  • 3 x 380 V
  • 3 x 460 V

Typical applications

  • Water circulation of closed cooling towers and condensers
  • Cooling of various unit equipment
  • Large-flow, low-head duties

Pumped liquid

  • Clean, thin, non-corrosive, non-flammable and non-explosive liquid without solid grains or fibres. A viscous or dense liquid lowers the performance curve and raises energy consumption.

Data basis

  • 50 Hz, 2900 / 1450 rpm, 3×380 V, clean water at 20 °C without solid impurities or air; use within the bold part of each curve
  • 60 Hz, 3450 / 3500 / 1750 / 1770 rpm, 3×460 V, clean water at 20 °C without solid impurities or air; use within the bold part of each curve

Performance values are taken from the published CNP catalogue data. Our engineers confirm the final selection for your liquid, temperature, supply and site before quoting.

Other cooling-tower pumps

Need a pump or a spare part?

Send us the flow and head you need, or the model code and nameplate details of the pump you are repairing. Our team replies with a quotation.