CNPPumps PakistanHESPAK Pvt. Ltd. Quote list0 Get a Quote
Vertical multistage centrifugal pump

CDL120-40

CDL / CDLF · 60 Hz · also listed as CDLF120-40

CDL120-40 is a vertical multistage centrifugal pump from the CNP CDL / CDLF range (60 Hz). Rated 75 kW, 60–160 m³/h, head 110–134 m. Net weight 675 kg.

  • Wide size range from 1 m³/h to 200 m³/h rated flow
  • Hot-water type available (up to +120 °C)
  • Standard IP55 / insulation class F two-pole motor

Performance curve Curve-based

05115051152Flow Q (m³/h)Head H (m)CDL120-40: Q 6 m³/h, H 134 mCDL120-40: Q 7 m³/h, H 133 mCDL120-40: Q 8 m³/h, H 132 mCDL120-40: Q 9 m³/h, H 131 mCDL120-40: Q 1 m³/h, H 129.5 mCDL120-40: Q 11 m³/h, H 127.5 mCDL120-40: Q 12 m³/h, H 125 mCDL120-40: Q 13 m³/h, H 122 mCDL120-40: Q 14 m³/h, H 119 mCDL120-40: Q 15 m³/h, H 114.5 mCDL120-40: Q 16 m³/h, H 109.5 m

Efficiency, shaft power and NPSHr are not published for this model in the source catalogue.

Head versus flow at 60 Hz, 3540 rpm, clean water. Source: Performance table, printed pp. 39–40.

Flow (m³/h)Head (m)
60134
70133
80132
90131
100129.5
110127.5
120125
130122
140119
150114.5
160109.5

Dimensions & weight

B2 = 845B1 = 1350B1+B2 = 2195D1 = 580D2 = 410Net weight: 675 kg
Outline drawn in proportion to this model's catalogue dimensions (simplified, only the labelled dimensions are shown). Codes match the table; confirm against the approved CNP drawing before installation.
CodeDescriptionValue
B1lower section height: base to motor flange1350 mm
B2upper section height: motor845 mm
B1+B2overall height2195 mm
D1motor diameter580 mm
D2base / flange width410 mm
—Net weight675 kg

Need a pump or a spare part?

Send us the flow and head you need, or the model code and nameplate details of the pump you are repairing. Our team replies with a quotation.