CNPPumps PakistanHESPAK Pvt. Ltd. Quote list0 Get a Quote
Non-clogging self-priming sewage pump

SP-10(750)

SP (self-priming sewage) · 50 Hz

SP-10(750) is a non-clogging self-priming sewage pump from the CNP SP (self-priming sewage) range (50 Hz). Rated 15 kW, 200–400 m³/h, head 6–10 m. Net weight 705 kg.

  • Flow 10–750 m³/h, head 3–38 m, motors 1.1–90 kW
  • Solids up to 38 mm (SP-2), 63 mm (SP-3), 76 mm (SP-4 to SP-10)
  • Rapid self-priming with a flap valve; maximum suction head printed per speed

Performance curve Curve-based

02.557.5113012345Flow Q (m³/h)Head H (m)SP-10(750): Q 2 m³/h, H 10 mSP-10(750): Q 3 m³/h, H 8.5 mSP-10(750): Q 4 m³/h, H 6 m

Efficiency, shaft power and NPSHr are not published for this model in the source catalogue.

Head versus flow at 50 Hz, 750 rpm, clean water. Source: Performance and operating tables, printed p. 17; dimensions pp. 20–26.

Flow (m³/h)Head (m)
20010
3008.5
4006

Dimensions & weight

L = 1244.7H = 1017Net weight: 705 kg
Outline drawn in proportion to this model's catalogue dimensions (simplified, only the labelled dimensions are shown). Codes match the table; confirm against the approved CNP drawing before installation.
CodeDescriptionValue
DNflange bore250 mm
Dflange outer diameter405 mm
D1bolt circle355 mm
D2raised face320 mm
nflange bolt holes12
d1flange bolt-hole diameter26 mm
H2H2639.8 mm
AA705 mm
A1A1635 mm
BB304.8 mm
B1B1101.6 mm
L2L2320.6 mm
d2foot bolt-hole diameter24 mm
H3H3355.6 mm
L3L3123 mm
dshaft diameter48 mm
Hoverall height, bare pump1017 mm
AmAm786 mm
H4H41047.8 mm
Loverall length, bare pump1244.7 mm
L4L4720.9 mm
E1E10 mm
E2E20 mm
cpl_AdCoupled set — Ad640 mm
cpl_Ld1Coupled set — Ld1150 mm
cpl_Ld2Coupled set — Ld21050 mm
cpl_dCoupled set — d24 mm
cpl_H11Coupled set — H11820 mm
cpl_H31Coupled set — H31535.6 mm
cpl_H41Coupled set — H411227.8 mm
cpl_KCoupled set — K2020 mm
cpl_AmCoupled set — Am786 mm
cpl_HmCoupled set — Hm1228 mm
cpl_HDCoupled set — HD880.6 mm
cpl_ECoupled set — E155.6 mm
cpl_LdCoupled set — Ld1350 mm
—Net weight705 kg

Need a pump or a spare part?

Send us the flow and head you need, or the model code and nameplate details of the pump you are repairing. Our team replies with a quotation.