CNPPumps PakistanHESPAK Pvt. Ltd. Quote list0 Get a Quote
In-line single-stage circulation pump

TD100-40G/2

TD (in-line circulation) · 50 Hz

TD100-40G/2 is an in-line single-stage circulation pump from the CNP TD (in-line circulation) range (50 Hz). Rated 18.5 kW, 10–130 m³/h, head 34–44 m. Net weight 220 kg.

  • Eleven sizes, DN32 to DN300, flow up to about 900 m³/h
  • Head up to about 100 m, 2-pole and 4-pole motors
  • Liquid from -15 to +110 °C, working pressure 12 bar (16 bar special)

Performance curve Curve-based

01234505115Flow Q (m³/h)Head H (m)TD100-40G/2: Q 1 m³/h, H 44.1 mTD100-40G/2: Q 2 m³/h, H 44.1 mTD100-40G/2: Q 3 m³/h, H 44 mTD100-40G/2: Q 4 m³/h, H 43.9 mTD100-40G/2: Q 5 m³/h, H 43.7 mTD100-40G/2: Q 6 m³/h, H 43.4 mTD100-40G/2: Q 7 m³/h, H 42.9 mTD100-40G/2: Q 8 m³/h, H 42.1 mTD100-40G/2: Q 9 m³/h, H 41.1 mTD100-40G/2: Q 1 m³/h, H 40 mTD100-40G/2: Q 11 m³/h, H 38.5 mTD100-40G/2: Q 12 m³/h, H 36.6 mTD100-40G/2: Q 13 m³/h, H 34.3 m

Efficiency, shaft power and NPSHr are not published for this model in the source catalogue.

Head versus flow at 50 Hz, 2900 rpm, clean water. Source: Performance table, PDF p. 19.

Flow (m³/h)Head (m)
1044.1
2044.1
3044
4043.9
5043.7
6043.4
7042.9
8042.1
9041.1
10040
11038.5
12036.6
13034.3

Dimensions & weight

Dimension codes in the table refer to the catalogue drawing.
CodeDescriptionValue
DD350 mm
B1B1314 mm
B2B2261 mm
B3B3181 mm
B4B4152 mm
B5B5230 mm
H1H1140 mm
H2H2257 mm
H3H3941 mm
L1L1550 mm
L2L2275 mm
—Net weight220 kg

Need a pump or a spare part?

Send us the flow and head you need, or the model code and nameplate details of the pump you are repairing. Our team replies with a quotation.