CNPPumps PakistanHESPAK Pvt. Ltd. Quote list0 Get a Quote
In-line single-stage circulation pump

TD100-52G/2

TD (in-line circulation) · 50 Hz

TD100-52G/2 is an in-line single-stage circulation pump from the CNP TD (in-line circulation) range (50 Hz). Rated 30 kW, 10–160 m³/h, head 41–59 m. Net weight 336 kg.

  • Eleven sizes, DN32 to DN300, flow up to about 900 m³/h
  • Head up to about 100 m, 2-pole and 4-pole motors
  • Liquid from -15 to +110 °C, working pressure 12 bar (16 bar special)

Performance curve Curve-based

02468051152Flow Q (m³/h)Head H (m)TD100-52G/2: Q 1 m³/h, H 59.1 mTD100-52G/2: Q 2 m³/h, H 58.9 mTD100-52G/2: Q 3 m³/h, H 58.7 mTD100-52G/2: Q 4 m³/h, H 58.4 mTD100-52G/2: Q 5 m³/h, H 58.2 mTD100-52G/2: Q 6 m³/h, H 57.8 mTD100-52G/2: Q 7 m³/h, H 57.3 mTD100-52G/2: Q 8 m³/h, H 56.9 mTD100-52G/2: Q 9 m³/h, H 56.4 mTD100-52G/2: Q 1 m³/h, H 55.8 mTD100-52G/2: Q 11 m³/h, H 55 mTD100-52G/2: Q 12 m³/h, H 53.9 mTD100-52G/2: Q 13 m³/h, H 52 mTD100-52G/2: Q 145 m³/h, H 47.7 mTD100-52G/2: Q 16 m³/h, H 40.8 m

Efficiency, shaft power and NPSHr are not published for this model in the source catalogue.

Head versus flow at 50 Hz, 2900 rpm, clean water. Source: Performance table, PDF p. 19.

Flow (m³/h)Head (m)
1059.1
2058.9
3058.7
4058.4
5058.2
6057.8
7057.3
8056.9
9056.4
10055.8
11055
12053.9
13052
14547.7
16040.8

Dimensions & weight

Dimension codes in the table refer to the catalogue drawing.
CodeDescriptionValue
DD400 mm
B1B1397 mm
B2B2314 mm
B3B3181 mm
B4B4152 mm
B5B5230 mm
H1H1140 mm
H2H2257 mm
H3H31049 mm
L1L1550 mm
L2L2275 mm
—Net weight336 kg

Need a pump or a spare part?

Send us the flow and head you need, or the model code and nameplate details of the pump you are repairing. Our team replies with a quotation.