CNPPumps PakistanHESPAK Pvt. Ltd. Quote list0 Get a Quote
In-line single-stage circulation pump

TD250-12.5/4

TD (in-line circulation) · 50 Hz

TD250-12.5/4 is an in-line single-stage circulation pump from the CNP TD (in-line circulation) range (50 Hz). Rated 30 kW, 240–750 m³/h, head 9–18 m. Net weight 552 kg.

  • Eleven sizes, DN32 to DN300, flow up to about 900 m³/h
  • Head up to about 100 m, 2-pole and 4-pole motors
  • Liquid from -15 to +110 °C, working pressure 12 bar (16 bar special)

Performance curve Curve-based

05115202468Flow Q (m³/h)Head H (m)TD250-12.5/4: Q 24 m³/h, H 18.4 mTD250-12.5/4: Q 3 m³/h, H 17.9 mTD250-12.5/4: Q 36 m³/h, H 17.2 mTD250-12.5/4: Q 42 m³/h, H 16.4 mTD250-12.5/4: Q 48 m³/h, H 15.5 mTD250-12.5/4: Q 54 m³/h, H 14.5 mTD250-12.5/4: Q 6 m³/h, H 13.2 mTD250-12.5/4: Q 63 m³/h, H 12.5 mTD250-12.5/4: Q 66 m³/h, H 11.8 mTD250-12.5/4: Q 72 m³/h, H 9.9 mTD250-12.5/4: Q 75 m³/h, H 8.7 m

Efficiency, shaft power and NPSHr are not published for this model in the source catalogue.

Head versus flow at 50 Hz, 1480 rpm, clean water. Source: Performance table, PDF p. 25.

Flow (m³/h)Head (m)
24018.4
30017.9
36017.2
42016.4
48015.5
54014.5
60013.2
63012.5
66011.8
7209.9
7508.7

Dimensions & weight

Dimension codes in the table refer to the catalogue drawing.
CodeDescriptionValue
DD400 mm
B1B1397 mm
B2B2314 mm
B3B3316 mm
B4B4243 mm
B5B5390 mm
H1H1300 mm
H2H2465 mm
H3H31417 mm
L1L11100 mm
L2L2550 mm
—Net weight552 kg

Need a pump or a spare part?

Send us the flow and head you need, or the model code and nameplate details of the pump you are repairing. Our team replies with a quotation.