CNPPumps PakistanHESPAK Pvt. Ltd. Quote list0 Get a Quote
In-line single-stage circulation pump

TD250-26/4

TD (in-line circulation) · 50 Hz

TD250-26/4 is an in-line single-stage circulation pump from the CNP TD (in-line circulation) range (50 Hz). Rated 75 kW, 240–750 m³/h, head 22–32 m. Net weight 909 kg.

  • Eleven sizes, DN32 to DN300, flow up to about 900 m³/h
  • Head up to about 100 m, 2-pole and 4-pole motors
  • Liquid from -15 to +110 °C, working pressure 12 bar (16 bar special)

Performance curve Curve-based

0123402468Flow Q (m³/h)Head H (m)TD250-26/4: Q 24 m³/h, H 31.7 mTD250-26/4: Q 3 m³/h, H 31.1 mTD250-26/4: Q 36 m³/h, H 30.6 mTD250-26/4: Q 42 m³/h, H 29.9 mTD250-26/4: Q 48 m³/h, H 29.1 mTD250-26/4: Q 54 m³/h, H 28.2 mTD250-26/4: Q 6 m³/h, H 26.8 mTD250-26/4: Q 63 m³/h, H 26 mTD250-26/4: Q 66 m³/h, H 25.2 mTD250-26/4: Q 72 m³/h, H 23.1 mTD250-26/4: Q 75 m³/h, H 21.9 m

Efficiency, shaft power and NPSHr are not published for this model in the source catalogue.

Head versus flow at 50 Hz, 1480 rpm, clean water. Source: Performance table, PDF p. 25.

Flow (m³/h)Head (m)
24031.7
30031.1
36030.6
42029.9
48029.1
54028.2
60026.8
63026
66025.2
72023.1
75021.9

Dimensions & weight

Dimension codes in the table refer to the catalogue drawing.
CodeDescriptionValue
DD550 mm
B1B1547 mm
B2B2407 mm
B3B3329 mm
B4B4264 mm
B5B5440 mm
H1H1300 mm
H2H2507 mm
H3H31667 mm
L1L11100 mm
L2L2550 mm
—Net weight909 kg

Need a pump or a spare part?

Send us the flow and head you need, or the model code and nameplate details of the pump you are repairing. Our team replies with a quotation.