CNPPumps PakistanHESPAK Pvt. Ltd. Quote list0 Get a Quote
In-line single-stage circulation pump

TD250-50/4

TD (in-line circulation) · 50 Hz

TD250-50/4 is an in-line single-stage circulation pump from the CNP TD (in-line circulation) range (50 Hz). Rated 132 kW, 240–750 m³/h, head 45–56 m. Net weight 1473 kg.

  • Eleven sizes, DN32 to DN300, flow up to about 900 m³/h
  • Head up to about 100 m, 2-pole and 4-pole motors
  • Liquid from -15 to +110 °C, working pressure 12 bar (16 bar special)

Performance curve Curve-based

024602468Flow Q (m³/h)Head H (m)TD250-50/4: Q 24 m³/h, H 55.6 mTD250-50/4: Q 3 m³/h, H 55.2 mTD250-50/4: Q 36 m³/h, H 54.6 mTD250-50/4: Q 42 m³/h, H 53.9 mTD250-50/4: Q 48 m³/h, H 53.2 mTD250-50/4: Q 54 m³/h, H 52.3 mTD250-50/4: Q 6 m³/h, H 50.9 mTD250-50/4: Q 63 m³/h, H 50 mTD250-50/4: Q 66 m³/h, H 49 mTD250-50/4: Q 72 m³/h, H 46.7 mTD250-50/4: Q 75 m³/h, H 45.4 m

Efficiency, shaft power and NPSHr are not published for this model in the source catalogue.

Head versus flow at 50 Hz, 1480 rpm, clean water. Source: Performance table, PDF p. 25.

Flow (m³/h)Head (m)
24055.6
30055.2
36054.6
42053.9
48053.2
54052.3
60050.9
63050
66049
72046.7
75045.4

Dimensions & weight

Dimension codes in the table refer to the catalogue drawing.
CodeDescriptionValue
DD660 mm
B1B1645 mm
B2B2535 mm
B3B3347 mm
B4B4292 mm
B5B5440 mm
H1H1305 mm
H2H2525 mm
H3H31990 mm
L1L11200 mm
L2L2600 mm
—Net weight1473 kg

Need a pump or a spare part?

Send us the flow and head you need, or the model code and nameplate details of the pump you are repairing. Our team replies with a quotation.