In-line single-stage circulation pump
TD65-37G/2
TD (in-line circulation) · 50 Hz
TD65-37G/2 is an in-line single-stage circulation pump from the CNP TD (in-line circulation) range (50 Hz). Rated 5.5 kW, 5–35 m³/h, head 32–40 m. Net weight 90 kg.
- Eleven sizes, DN32 to DN300, flow up to about 900 m³/h
- Head up to about 100 m, 2-pole and 4-pole motors
- Liquid from -15 to +110 °C, working pressure 12 bar (16 bar special)
Performance curve Curve-based
Efficiency, shaft power and NPSHr are not published for this model in the source catalogue.
Head versus flow at 50 Hz, 2900 rpm, clean water. Source: Performance table, PDF p. 15.
| Flow (m³/h) | Head (m) |
|---|---|
| 5 | 39.6 |
| 10 | 39.3 |
| 15 | 39 |
| 20 | 38.2 |
| 25 | 37 |
| 30 | 35 |
| 35 | 32.1 |
Dimensions & weight
| Code | Description | Value |
|---|---|---|
| D | D | 200 mm |
| B1 | B1 | 257 mm |
| B2 | B2 | 190 mm |
| B3 | B3 | 128 mm |
| B4 | B4 | 128 mm |
| B5 | B5 | 144 mm |
| H1 | H1 | 105 mm |
| H2 | H2 | 180 mm |
| H3 | H3 | 668 mm |
| L1 | L1 | 400 mm |
| L2 | L2 | 200 mm |
| — | Net weight | 90 kg |