In-line single-stage circulation pump
TD100-34/2
TD (in-line circulation) · 60 Hz
TD100-34/2 is an in-line single-stage circulation pump from the CNP TD (in-line circulation) range (60 Hz). Rated 18.5 kW, 10–140 m³/h, head 31–39 m. Net weight 224 kg.
- Eleven sizes, DN32 to DN300, flow up to about 900 m³/h
- Head up to about 100 m, 2-pole and 4-pole motors
- Liquid from -15 to +110 °C, working pressure 12 bar (16 bar special)
Performance curve Curve-based
Efficiency, shaft power and NPSHr are not published for this model in the source catalogue.
Head versus flow at 60 Hz, 3500 rpm, clean water. Source: Performance table, PDF p. 32.
| Flow (m³/h) | Head (m) |
|---|---|
| 10 | 39.4 |
| 20 | 39.4 |
| 40 | 39.5 |
| 50 | 39.2 |
| 60 | 39 |
| 80 | 37.8 |
| 100 | 36.2 |
| 120 | 34 |
| 130 | 33.4 |
| 140 | 31 |
Dimensions & weight
| Code | Description | Value |
|---|---|---|
| D | D | 350 mm |
| B1 | B1 | 350 mm |
| B2 | B2 | 265 mm |
| B3 | B3 | 181 mm |
| B4 | B4 | 152 mm |
| B5 | B5 | 230 mm |
| H1 | H1 | 140 mm |
| H2 | H2 | 270 mm |
| H3 | H3 | 960 mm |
| L1 | L1 | 550 mm |
| L2 | L2 | 275 mm |
| — | Net weight | 224 kg |