CNPPumps PakistanHESPAK Pvt. Ltd. Quote list0 Get a Quote
In-line single-stage circulation pump

TD125-28/4

TD (in-line circulation) · 60 Hz

TD125-28/4 is an in-line single-stage circulation pump from the CNP TD (in-line circulation) range (60 Hz). Rated 18.5 kW, 20–200 m³/h, head 23–30 m. Net weight 321 kg.

  • Eleven sizes, DN32 to DN300, flow up to about 900 m³/h
  • Head up to about 100 m, 2-pole and 4-pole motors
  • Liquid from -15 to +110 °C, working pressure 12 bar (16 bar special)

Performance curve Curve-based

0123405115225Flow Q (m³/h)Head H (m)TD125-28/4: Q 2 m³/h, H 30.4 mTD125-28/4: Q 4 m³/h, H 30.2 mTD125-28/4: Q 6 m³/h, H 30.1 mTD125-28/4: Q 8 m³/h, H 29.9 mTD125-28/4: Q 1 m³/h, H 29.4 mTD125-28/4: Q 12 m³/h, H 28.6 mTD125-28/4: Q 14 m³/h, H 28 mTD125-28/4: Q 15 m³/h, H 27.3 mTD125-28/4: Q 16 m³/h, H 26.6 mTD125-28/4: Q 18 m³/h, H 24.5 mTD125-28/4: Q 2 m³/h, H 22.5 m

Efficiency, shaft power and NPSHr are not published for this model in the source catalogue.

Head versus flow at 60 Hz, 1750 rpm, clean water. Source: Performance table, PDF p. 33.

Flow (m³/h)Head (m)
2030.4
4030.2
6030.1
8029.9
10029.4
12028.6
14028
15027.3
16026.6
18024.5
20022.5

Dimensions & weight

Dimension codes in the table refer to the catalogue drawing.
CodeDescriptionValue
DD350 mm
B1B1330 mm
B2B2255 mm
B3B3236 mm
B4B4208 mm
B5B5230 mm
H1H1215 mm
H2H2298 mm
H3H31090 mm
L1L1800 mm
L2L2400 mm
—Net weight321 kg

Need a pump or a spare part?

Send us the flow and head you need, or the model code and nameplate details of the pump you are repairing. Our team replies with a quotation.