CNPPumps PakistanHESPAK Pvt. Ltd. Quote list0 Get a Quote
Variable-frequency in-line single-stage pump

TDE32-21G/2

TDE (variable-frequency in-line) · 50 Hz

TDE32-21G/2 is a variable-frequency in-line single-stage pump from the CNP TDE (variable-frequency in-line) range (50 Hz). Rated 1.5 kW, 2–16 m³/h, head 18–25 m. Net weight 42 kg.

  • Six sizes, DN32 to DN100, 47 models, 1.5 to 15 kW
  • Controller output 30–50 Hz, IP55, LCD display
  • Five control modes and multi-pump coordination (main plus up to five auxiliary pumps)

Performance curve Curve-based

0123051152Flow Q (m³/h)Head H (m)TDE32-21G/2: Q 2 m³/h, H 25.3 mTDE32-21G/2: Q 4 m³/h, H 24.9 mTDE32-21G/2: Q 6 m³/h, H 24.3 mTDE32-21G/2: Q 8 m³/h, H 23.6 mTDE32-21G/2: Q 1 m³/h, H 22.6 mTDE32-21G/2: Q 13 m³/h, H 21 mTDE32-21G/2: Q 14 m³/h, H 19.9 mTDE32-21G/2: Q 16 m³/h, H 18 m

Efficiency, shaft power and NPSHr are not published for this model in the source catalogue.

Head versus flow at 50 Hz, 2900 rpm, clean water. Source: Performance table, PDF p. 5.

Flow (m³/h)Head (m)
225.3
424.9
624.3
823.6
1022.6
12.521
1419.9
1618

Dimensions & weight

Dimension codes in the table refer to the catalogue drawing.
CodeDescriptionValue
D1D1140 mm
D2D2186 mm
B1B1172 mm
B2B2217 mm
B3B3101 mm
B4B4101 mm
B5B5144 mm
H1H190 mm
H2H2137 mm
H3H3514 mm
L1L1320 mm
L2L2160 mm
—Net weight42 kg

Need a pump or a spare part?

Send us the flow and head you need, or the model code and nameplate details of the pump you are repairing. Our team replies with a quotation.